Calculate generic first-order temperature drift for electronics parameters such as resistance, voltage, gain, capacitance, sensor output, frequency or another consistent quantity.

THM-012 is intentionally generic. It does not replace NTC thermistor curves, PT100/PT1000 RTD equations, crystal oscillator compensation models or device-specific resistor TCR data.

Engineering tool

Temperature Coefficient Calculator

Calculate first-order linear temperature drift using relative ppm/% coefficients or absolute quantity-per-degree coefficients.

Calculation mode

Calculate X(T) from Xref, alpha, Tref and target temperature.

Use one consistent unit for Xref, measured value and target value. Examples: ohm, V, Hz, pF, lux.

unit

Reference value at Tref. May be zero in forward modes, but inverse relative coefficient modes require nonzero Xref.

Relative coefficient alpha. Positive, zero and negative coefficients are allowed.

Reference absolute temperature.

Target or second absolute temperature.

Result console

Final Value
100.5unit
Absolute Change
0.5unit
Fractional Change
0.005
Percentage Change
0.5%
PPM Change
5000ppm
Temperature Difference
50K
Absolute Coefficient
0.01unit/K

Formula

Formula reference

Linear temperature coefficient formulas

Fahrenheit temperature differences are converted by 5/9 before using the kelvin-sized temperature interval.

X(T) = Xref [1 + alpha(T - Tref)]Delta T = T - Trefdelta = alpha Delta T% change = 100 alpha Delta Tppm change = 1,000,000 alpha Delta TDelta X = Xref alpha Delta Talpha = (X2/Xref - 1) / (T2 - Tref)Xref = X / (1 + alpha Delta T)Delta T = (X/Xref - 1) / alphaAbsolute model: X(T) = Xref + beta Delta T

Variable definitions

Xref
reference value at the reference temperature
X(T)
value at the target temperature
alpha
relative temperature coefficient in 1/K
beta
absolute temperature coefficient in quantity units per K
Delta T
temperature interval in K or °C-equivalent units

Temperature Coefficient Formula Audit

Relative Linear ModelX(T)=Xref[1+alpha(T-Tref)].
Temperature Difference FormulaDelta T = T - Tref, using kelvin-sized intervals.
Fractional Change Formuladelta = alpha Delta T.
Percentage Change Formula% change = 100 alpha Delta T.
Absolute Change FormulaDelta X = Xref alpha Delta T.
Coefficient From Two Points Formulaalpha = (X2/Xref - 1)/(T2-Tref).
Reference Value Inverse FormulaXref = X/(1+alpha Delta T).
Target Temperature Inverse FormulaDelta T = (X/Xref - 1)/alpha.
PPM Conversionppm = fraction x 1,000,000.
Percent Conversionpercent = fraction x 100.
Celsius/Kelvin Coefficient ConventionPer °C and per K coefficients are numerically equivalent for intervals.
Fahrenheit Difference ConventionFahrenheit intervals use 5/9 to convert to kelvin-sized intervals.
Fahrenheit Coefficient Conventionalpha per °F = alpha per K / 1.8.
Positive Coefficient PolicyPositive alpha increases X as temperature rises.
Negative Coefficient PolicyNegative alpha is allowed and decreases X as temperature rises.
Zero Coefficient PolicyForward X remains Xref; inverse target temperature is unreachable or indeterminate.
Zero Reference Inverse PolicyRelative coefficient-from-points and target-temperature modes reject Xref=0.
Zero Temperature Difference Inverse PolicyCoefficient-from-points rejects T2=Tref.
Inverse Denominator Policy1+alpha Delta T close to zero is rejected before division.
Relative vs Absolute Coefficient BoundaryAlpha uses relative units; beta uses quantity units per degree.
Linear Approximation BoundaryConstant alpha is a first-order approximation, not a nonlinear device model.
Large Drift Warning PolicyA warning appears when |alpha Delta T| exceeds 0.1.
NTC BoundaryNTC Beta and Steinhart-Hart calculations remain in THM-005.
RTD BoundaryPT100/PT1000 IEC behavior remains in THM-006.
Resistor TCR BoundaryDevice-specific resistor TCR tables remain with resistor references and datasheets.
Capacitor BoundaryClass II ceramic capacitance can be nonlinear with temperature, DC bias and aging.
Oscillator BoundaryCrystal and oscillator temperature behavior can be parabolic or compensated.
Sensor BoundarySensor calibration and nonlinear transfer functions remain in Sensors.
Initial Tolerance BoundaryInitial tolerance is not the same as temperature coefficient.
Internal Precision PolicyCalculations use full precision; formatting occurs only in the display layer.

Worked Examples

InputCalculationResult
100 ppm/K100 x 1e-60.0001 /K
100 ppm/K0.0001 x 1000.01 %/K
0.5 %/K0.5 / 1000.005 /K
0.5 %/K0.005 x 1e65000 ppm/K
Xref=100, alpha=100 ppm/K, Delta T=50Kdelta = 0.0001 x 500.005
Samepercent = 100 x 0.0050.5%
SameDelta X = 100 x 0.0050.5
SameX = 100 + 0.5100.5
Delta T=-50KX = 100(1 - 0.005)99.5
alpha=-100 ppm/K, Delta T=50KX = 100(1 - 0.005)99.5
alpha=0X = Xref(1+0)X = Xref
T=TrefDelta T=0X = Xref
Xref=100, X2=100.5, Delta T=50K(100.5/100 - 1)/50100 ppm/K
Samealpha in 1/K0.0001 /K
Samealpha x 1000.01 %/K
Xref=0 coefficient inverserelative denominator unavailablerejected
Delta T=0 coefficient inversedivision by zero avoidedrejected
X=100.5, alpha=100 ppm/K, Delta T=50K100.5 / 1.005Xref=100
Xref=100, target=100.5, alpha=100 ppm/K(1.005 - 1)/0.0001Delta T=50K
Tref=25°C plus 50K25 + 5075°C
alpha=0, target != Xrefno first-order changeunreachable
alpha=0, target = Xrefall temperatures satisfyindeterminate
250 ppm/K250 x 1e-60.00025 /K
250 ppm/K0.00025 x 1000.025 %/K
1 %/K0.01 x 1e610000 ppm/K
1 ppm/K1e-6 x 1000.0001 %/K
25°C to 75°C75 - 2550K
298.15K to 348.15Ksame Celsius endpoints50K
77°F to 167°F(167 - 77) x 5/950K
100 ppm/K over 90°F difference100 ppm/K over 50K0.5% change
100 ppm/K coefficient100 / 1.855.5556 ppm/°F
Xref=100 ohm, alpha=100 ppm/Kbeta = alpha Xref0.01 ohm/K
Xref=5V, beta=-2mV/K, Delta T=50KDelta X=-0.1V4.9V
positive alpha + positive Delta Tpositive deltapositive drift
negative alpha + positive Delta Tnegative deltanegative drift
positive alpha + negative Delta Tnegative deltanegative drift
alpha Delta T near -1inverse denominator close to zerosafe rejection
0.001 ppm/K over 0.001K1e-9 x 0.0011e-12 fraction retained
NaN inputfinite validationrejected
Infinity inputfinite validationrejected

Engineering Notes

Temperature CoefficientThe calculator uses a first-order coefficient that relates value change to temperature change.
Relative Temperature CoefficientRelative alpha is normalized by Xref and expressed in 1/K, %/K or ppm/K.
Absolute Temperature CoefficientAbsolute beta is expressed in quantity units per degree, such as mV/K, ohm/K or Hz/K.
Reference ValueXref is the value at the reference temperature and must use the same unit as all X values.
Reference TemperatureTref anchors the linear model; calculations use T - Tref, not absolute temperature alone.
Temperature DriftDrift is the signed change from Xref caused by the modeled temperature interval.
Fractional ChangeFractional change is alpha Delta T before percent or ppm scaling.
PPM per DegreeOne ppm is 10^-6, so 100 ppm/K equals 0.0001/K.
Positive Temperature CoefficientA positive coefficient produces higher value at higher temperature.
Negative Temperature CoefficientA negative coefficient produces lower value at higher temperature.
Linear ApproximationAlpha is assumed constant over the interval. Real components can be nonlinear.
TCRResistor TCR can be estimated with this model only when the datasheet supports a linear range.
Temperature RangeUse coefficients only over the temperature span for which they are specified.
Initial ToleranceInitial tolerance and temperature coefficient are separate error terms.
NonlinearityNTCs, RTDs, ceramic capacitors and crystals can require specialized models.

Common Mistakes

  • • Treating ppm as percent.
  • • Entering 100 ppm as 100%.
  • • Forgetting the 1e-6 ppm factor.
  • • Treating 0.01% as 0.01 instead of 0.0001.
  • • Multiplying the coefficient by absolute temperature instead of T - Tref.
  • • Using a Fahrenheit interval as if it were a kelvin interval.
  • • Confusing temperature coefficient with initial tolerance.
  • • Forcing a negative coefficient to be positive.
  • • Trying to derive a relative coefficient from Xref=0.
  • • Trying to derive a coefficient from two equal temperatures.
  • • Using constant alpha for an NTC thermistor over a wide range.
  • • Replacing an RTD Callendar-Van Dusen model with a generic alpha.
  • • Treating one generic temperature coefficient as an exact model for all devices.
  • • Rounding tiny ppm values before the final display.

NTC Thermistor Calculator

Available

Use the nonlinear Beta or Steinhart-Hart thermistor model instead of generic alpha.

Open calculator

RTD PT100 / PT1000 Calculator

Available

Calculate platinum RTD resistance and temperature using IEC 60751 equations.

Open calculator

Thermal Derating Calculator

Available

Calculate datasheet rating reduction versus temperature from derating curves.

Open calculator

Oscillator Frequency Tolerance & PPM Calculator

Available

Estimate oscillator ppm, clock drift and temperature stability error budgets.

Open calculator

PCB Trace Voltage Drop Calculator

Available

Calculate copper resistance and voltage drop with temperature-adjusted resistivity.

Open calculator

Documentation

Guides and lookup references linked to this tool.

Support reference

FAQ

What is a temperature coefficient?

A temperature coefficient describes how a quantity changes with temperature. This calculator uses a first-order linear coefficient around a reference temperature.

How do I calculate temperature coefficient?

For two measured points, use alpha = (X2 / Xref - 1) / (T2 - Tref), where Xref is nonzero and the temperature difference is nonzero.

What is the formula for temperature coefficient?

The relative linear model is X(T) = Xref[1 + alpha(T - Tref)]. The coefficient alpha is normally in 1/K, percent per K, or ppm per K.

What does ppm/°C mean?

ppm/°C means parts per million change per degree Celsius temperature interval. One ppm is 0.000001 of the reference value.

What does ppm/K mean?

ppm/K means parts per million change per kelvin temperature interval. For temperature intervals, ppm/K and ppm/°C are numerically equivalent.

Are ppm/°C and ppm/K the same?

They are the same for temperature differences because a 1 °C interval equals a 1 K interval. Absolute Celsius and kelvin temperatures are not numerically the same.

How do I convert ppm/°C to percent per degree?

Divide ppm by 10000. For example, 100 ppm/°C equals 0.01%/°C.

How do I convert percent per degree to ppm?

Multiply percent per degree by 10000. For example, 0.5%/K equals 5000 ppm/K.

What does 100 ppm/°C mean?

It means the quantity changes by 100 parts per million per °C. Over 50 °C, the first-order change is 5000 ppm, or 0.5%.

How do I calculate a value at a different temperature?

Convert the coefficient to 1/K, calculate delta T = T - Tref, then use X = Xref(1 + alpha delta T).

How do I calculate temperature drift?

Use delta X = Xref alpha delta T for a relative coefficient, or delta X = beta delta T for an absolute coefficient.

How do I calculate temperature coefficient from two measurements?

Use alpha = (X2 - Xref) / (Xref delta T). Xref must be nonzero because the coefficient is relative to the reference value.

What is a positive temperature coefficient?

A positive coefficient means the modeled quantity increases as temperature increases.

What is a negative temperature coefficient?

A negative coefficient means the modeled quantity decreases as temperature increases.

Can a temperature coefficient be zero?

Yes. A zero coefficient means the first-order model predicts no temperature dependence.

What is the difference between temperature coefficient and tolerance?

Tolerance describes initial value spread. Temperature coefficient describes change with temperature after the reference value is defined.

What is the difference between relative and absolute temperature coefficient?

A relative coefficient uses 1/K, percent per K, or ppm/K. An absolute coefficient uses quantity units per K, such as mV/K, ohm/K, or Hz/K.

How do I convert an absolute coefficient to ppm?

Divide the absolute coefficient by the nonzero reference value to get 1/K, then multiply by one million.

Why is a reference value required for ppm conversion?

PPM is relative. Without a nonzero reference value, an absolute change per degree cannot be normalized.

How do Fahrenheit temperature differences affect temperature coefficients?

A Fahrenheit interval must be converted by 5/9 when used as a kelvin interval. A coefficient per °F is smaller than the equivalent per K by a factor of 1.8.

Is the temperature coefficient always linear?

No. This calculator assumes a constant coefficient over the interval. Real parts can be nonlinear, piecewise, or table based.

Can I use this calculator for resistors?

Yes for a first-order resistor TCR estimate over a valid range, but resistor-specific color code and material data belong to resistor tools and datasheets.

Can I use this calculator for NTC thermistors?

Not for wide temperature ranges. NTC thermistors are strongly nonlinear and should use the NTC Thermistor Calculator.

Can I use this calculator for PT100 or PT1000 RTDs?

Use the RTD PT100/PT1000 Calculator for IEC 60751 RTD behavior instead of replacing the full curve with a generic constant alpha.

Disclaimer

This calculator provides first-order engineering estimates. Critical designs should be verified against device datasheets, temperature ranges, nonlinear models, simulation and measurement.