Thermal Derating Calculator

Calculate generic datasheet thermal derating for power, current, load or another rated quantity. Enter the rated value, reference temperature, slope, zero-rating endpoint, or two datasheet points to estimate allowable rating at operating temperature.

THM-004 does not invent a component derating curve. Use manufacturer datasheets or qualified engineering data, and keep ambient, case, board and junction temperature bases separate.

Engineering tool

Thermal Derating Calculator

Calculate generic datasheet linear thermal derating for power, current, load, or another rated quantity.

Calculation mode

Calculate allowable rating from a datasheet slope in rating units per degree.

Label for the generic rated quantity.

Display unit for rating values, such as W, A, %, or load units.

Used as a label only. This calculator does not convert ambient, case, board, and junction temperatures.

Absolute temperature unit for all temperature fields.

Rated power at or below the reference temperature.

Temperature where derating begins.

Temperature at which the derated rating is evaluated.

Absolute slope in W per temperature interval.

Result console

Allowable Rating
4W
Remaining Rating
40%
Derating Amount
6W
Raw Mathematical Rating
4W
Temperature Above Reference
30°C
Status
Within modeled derated rating
Zero-Rating Temperature
120°C

The allowable rating follows the entered linear datasheet derating model.

Formula

Formula reference

Linear thermal derating formulas

The calculator assumes full rating at or below the reference temperature and clamps negative user-facing allowable ratings to zero.

Xallow = Xrated for T <= TrefXallow = Xrated - D(T - Tref) for T > TrefPercentage: Xallow = Xrated × [1 - (d/100)(T - Tref)]Two point: D = (X1 - X2) / (T2 - T1)Zero endpoint: D = Xrated / (Tzero - Tref)Tzero = Tref + Xrated / DTmax = Tref + (Xrated - Xrequired) / DMargin = Xallow - XappliedUtilization = Xapplied / Xallow × 100%

Variable definitions

Xrated
rated value at or below reference temperature
Xallow
allowable derated value
D
absolute derating slope
d
percentage-point derating slope
Tref
derating reference temperature
Tzero
zero-rating endpoint

Thermal Derating Formula Audit

Linear Derating FormulaXallow = Xrated - D(T - Tref) for T > Tref.
Percentage Derating FormulaXallow = Xrated × [1 - (d/100)(T - Tref)].
Percentage Semanticsd is percentage points of original rated value per degree.
Two-Point Slope FormulaD = (X1 - X2) / (T2 - T1).
Zero-Rating Slope FormulaD = Xrated / (Tzero - Tref).
Zero-Rating Temperature FormulaTzero = Tref + Xrated / D for D > 0.
Maximum Operating Temperature FormulaTmax = Tref + (Xrated - Xrequired) / D.
Rating Margin FormulaMargin = Xallow - Xapplied.
Utilization FormulaUtilization = Xapplied / Xallow × 100% when Xallow > 0.
Below-Reference PolicyFull rating is assumed at or below Tref; rating is not increased.
At-Reference PolicyXallow = Xrated.
Zero-Rating Clamp PolicyUser-facing allowable rating is clamped to zero.
Above-Zero-Rating PolicyRaw negative value is retained for status, not displayed as valid allowance.
Zero-Slope PolicyForward rating remains constant; inverse temperature has no finite derating-derived limit.
Negative-Slope PolicyRejected because V1 models normal thermal derating only.
Temperature Basis PolicyAmbient, case, board and junction are labels only; no automatic conversion between them.
Absolute Temperature ConventionAbsolute temperatures are converted to °C internally.
Temperature Interval ConventionSlopes use temperature intervals, not absolute temperature conversion.
°C/K Slope Equivalenceunit/°C and unit/K are numerically equal.
°F Slope Conventionper-°F slopes are converted using interval scale.
Linear-Model BoundaryNonlinear or piecewise curves must be handled from datasheet segments.
Datasheet Authority BoundaryThe calculator does not invent derating curves.
THM-001 Scope SeparationTHM-004 does not calculate ΔT = P × Rθ.
THM-002 Scope SeparationTHM-004 does not size heatsinks.
THM-003 Scope SeparationTHM-004 does not combine thermal resistance networks.

Worked Examples

InputCalculationResult
10 W, Tref 70°C, D 0.2 W/°C, T 100°CΔT = 30°C, derating = 6 W4 W, 40% remaining
Same at 70°CT = Tref10 W
Same at 50°CBelow Tref10 W, not 14 W
Same at 120°C10 - 0.2(50)0 W
Same at 130°Craw = -2 Wdisplayed 0 W, beyond zero rating
50 W, Tref 50°C, d 1%/°C, T 80°C30 percentage points lost35 W, 70% remaining
Same at 50°Cno excess temperature50 W
Same at 150°C100 percentage points lost0 W
70°C → 10 W, 120°C → 0 WD = 10 / 500.2 W/°C
Same two-point model at 100°C10 - 0.2(30)4 W
10 W, Tref 70°C, Tzero 120°CD = 10 / 500.2 W/°C
Same at 95°C10 × (120 - 95)/(120 - 70)5 W
10 W, Tref 70°C, D 0.2, required 6 WTmax = 70 + (10 - 6)/0.290°C
Same, required 10 WTmax = Tref70°C
Required 11 Wrequired > ratedrejected / invalid requirement
Slope = 0, T > Trefno deratingrated value remains
Slope = 0 inversedivision by zero avoidedN/A
Allowable 6 W, applied 5 Wmargin = 1 Wpass
Allowable 6 W, applied 6 Wmargin = 0 Wat limit
Allowable 6 W, applied 7 Wmargin = -1 Wfail
Allowable 5 W, applied 4 W4 / 5 × 10080% utilization
Allowable 0, applied > 0division by zero avoidedN/A utilization
T2 <= T1invalid point orderrejected
X2 > X1increasing ratingrejected
Negative slopeoutside derating modelrejected
Rated value <= 0invalid nameplate ratingrejected
Temperature below 0 Kabsolute temperature invalidrejected
1 unit/°C and 1 unit/Kinterval scales matchsame result
0.18 W/°F0.18 × 1.80.324 W/°C
1%/°Cpercentage points, not 0.99^ΔTlinear remaining percent

Engineering Notes

Thermal Derating

Thermal derating reduces an allowable rating as temperature increases according to a specified model.

Rated Value

The rated value is the datasheet rating at or below the derating start temperature.

Reference Temperature

The reference or derating-start temperature is where the modeled reduction begins.

Derating Slope

The absolute slope is rating units lost per temperature interval.

Percentage Derating

Percentage slope is interpreted as percentage points of original rating per degree.

Zero-Rating Temperature

Tzero is the datasheet endpoint where the modeled rating reaches zero, not automatically Tjmax.

Two-Point Derating

Two datasheet points can define a slope when the curve is linear between them.

Temperature Basis

Ambient, case, board and junction temperature are different quantities.

Linear Derating Model

Use this only where source data specifies or supports a linear relationship.

Datasheet Derating Curve

The calculator does not infer derating data; users must enter values from qualified sources.

Absolute Maximum Rating

Absolute maximum limits and recommended derated operating limits are not the same.

Operating Margin

Applied-load margin keeps its sign so failures remain visible.

Common Mistakes

  • Implementing 1%/°C as exponential decay.
  • Increasing the rating below the reference temperature.
  • Treating Tzero as maximum junction temperature.
  • Mixing ambient, case, board and junction temperature bases.
  • Using the wrong datasheet temperature basis.
  • Displaying negative allowable power as a valid rating.
  • Taking the absolute value of rating margin.
  • Displaying Infinity utilization when allowable rating is zero.
  • Returning Infinity for inverse maximum temperature when slope is zero.
  • Using absolute Fahrenheit conversion for slope.
  • Treating °C and K absolute temperatures as numerically identical.
  • Forcing one straight line onto a nonlinear datasheet curve.
  • Treating derated rating as guaranteed lifetime.
  • Treating absolute maximum rating as recommended operating rating.

Support reference

FAQ

What is thermal derating?

Thermal derating reduces an allowable rating as temperature increases according to a datasheet or engineering specification.

How do I calculate power derating with temperature?

Use Xallow = Xrated - D(T - Tref) above the reference temperature, then clamp negative allowable values to zero.

What is a derating slope?

A derating slope is the amount of rating lost per degree above a reference temperature, such as watts per °C.

How do I calculate allowable power at a higher temperature?

Subtract slope times temperature rise above the derating reference temperature from the rated value.

What does %/°C derating mean?

%/°C is interpreted as percentage points of the original rated value lost per degree.

Is 1%/°C an exponential reduction?

No. THM-004 treats 1%/°C as one percentage point of original rating per °C, not Xrated × 0.99^ΔT.

How do I calculate a derating slope from two datasheet points?

Use D = (X1 - X2) / (T2 - T1), where T2 must be greater than T1 and X2 must not exceed X1.

How do I calculate zero-rating temperature?

For a positive absolute slope, Tzero = Tref + Xrated / D.

How do I calculate maximum operating temperature for a required load?

Use Tmax = Tref + (Xrated - Xrequired) / D. If required value exceeds rated value, the requirement is invalid under this model.

What happens below the derating reference temperature?

This calculator assumes full rated value at or below the reference temperature and does not increase rating below Tref.

What happens above the zero-rating temperature?

The raw linear result may be negative, but the user-facing allowable rating is clamped to zero.

Can allowable rating become negative?

The raw mathematical value can become negative, but the valid engineering allowable rating is shown as zero.

What is the difference between ambient, case and junction temperature derating?

They are different temperature bases. Use the same basis specified by the datasheet curve.

Can I use a junction-temperature curve with ambient temperature?

Not directly. THM-004 does not convert Ta, Tc, board temperature and Tj. Use the datasheet-defined basis.

Is °C-based derating the same as K-based derating?

For temperature intervals, °C and K slopes are numerically equivalent.

How does °F affect derating slope?

A per-°F slope must be converted by interval scale. 0.18 W/°F equals 0.324 W/°C.

Is thermal derating the same as thermal resistance?

No. Thermal resistance predicts temperature rise from heat flow. Derating interprets an allowable rating versus temperature curve.

Does derating guarantee component lifetime?

No. Derating improves operating margin but does not guarantee lifetime, MTBF, or reliability.

What is the difference between derating and absolute maximum rating?

Absolute maximum ratings are stress limits. Recommended derated operating limits are normally more conservative application limits.

Where should I get the derating parameters?

Use the manufacturer datasheet, application note, qualification data, or an approved engineering specification.

Thermal Resistance & Temperature Rise Calculator

Available

Use THM-001 for temperature rise and thermal power from a known equivalent Rθ.

Open calculator →

Heat Sink Thermal Resistance Calculator

Available

Use THM-002 for heatsink RθSA and junction temperature checks.

Open calculator →

Thermal Resistance Network Calculator

Available

Use THM-003 to combine multiple thermal resistance paths before applying temperature limits.

Open calculator →

Power Dissipation Calculator

Available

Calculate component heat load and compare against rating and margin.

Open calculator →

MOSFET Junction Temperature Calculator

Available

Estimate MOSFET junction temperature before comparing against derating data.

Open calculator →

High Power LED Thermal Calculator

Available

Check LED junction temperature and thermal margin under real operating power.

Open calculator →

Diode Power Dissipation Calculator

Available

Estimate diode power loss and thermal margin before derating review.

Open calculator →

Documentation

Guides and lookup references linked to this tool.