Engineering Guide
AC Power Factor, Supply Current, Voltage Drop, and Runtime Budgeting
A useful power budget follows energy from the source through conversion and distribution to the load. Real power, apparent power, current, voltage drop, usable battery energy, peak demand, and time-weighted runtime must remain distinct.
Source-to-Load Workflow
| Step | Action | Engineering Check |
|---|---|---|
| Define load states | List operating, peak, startup, standby, sleep, and fault power with duration or duty cycle. | |
| Separate AC quantities | Keep real power, apparent power, reactive power, displacement, distortion, RMS voltage, and RMS current distinct. | |
| Refer load to source | Include converter efficiency, power factor, quiescent demand, and simultaneous-load assumptions. | |
| Size current paths | Calculate continuous, peak, and transient current at each voltage rail rather than transferring current unchanged between rails. | |
| Budget distribution | Calculate source, cable, connector, switch, fuse, and PCB voltage drops at the relevant current and temperature. | |
| Budget energy | Convert capacity to usable watt-hours at the actual voltage, discharge rate, temperature, and SOC window. | |
| Estimate runtime | Divide usable energy by time-weighted average input power, then check peak-current and cutoff constraints. | |
| Validate | Measure RMS input, real power, rail current, endpoint voltage, temperature, capacity, and shutdown behavior over corners. |
Power and Energy Quantities
| Quantity | Meaning | Unit or Boundary |
|---|---|---|
| Real power P | Energy converted per unit time | W |
| Apparent power S | Vrms x Irms | VA |
| Reactive power Q | Quadrature power component for sinusoidal conditions | var |
| Power factor | P/S | Dimensionless; includes waveform distortion in total PF |
| DC load power | Vload x Iload | W |
| Source input power | Pload/efficiency plus other losses | W |
| Voltage drop | Current x path resistance | V |
| Battery energy | Voltage x ampere-hours | Wh; voltage is operating-point dependent |
| Runtime | Usable energy/average input power | h; only a first-order energy estimate |
AC Power Factor and Source Current
Formula reference
Single-phase source model
S = Vrms x IrmsPF = P/SIrms = P/(Vrms x PF)Q = sqrt(S squared - P squared) for the applicable sinusoidal modelVariable definitions
- Total PF includes displacement and distortion
- Use true RMS measurements for nonsinusoidal current
- Efficiency is not power factor
Use the Power Factor Calculator for AC relationships.
Supply Current and Distribution
Formula reference
Conversion and path model
Pinput = Pload/efficiencyIdc,input = Pinput/VinputVdrop = I x RpathPloss,path = I squared x RpathVload = Vsource - VdropVariable definitions
- Use source-side current for source wiring
- Rpath includes the complete loop
- Check continuous and peak states separately
Use the Power Supply Current Calculator and verify delivery with the Voltage Drop Calculator.
Battery Energy and Runtime
Formula reference
First-order energy budget
Enominal(Wh) approximately Vnominal x Capacity(Ah)Eusable = Enominal x usable fraction x conversion efficiencyPaverage = sum(Pstate x duty state)Runtime = Eusable/PaverageVariable definitions
- Actual battery voltage changes during discharge
- Rate, temperature, aging, cutoff, and peaks reduce usable energy
- Do not use rounded display values in chained calculations
Use the Battery Capacity Runtime Calculator for an energy estimate and validate against the battery discharge specification.
Worked Examples
AC current
A 500 W load at 230 V and PF 0.8 draws about 2.72 A RMS, not 2.17 A.
Apparent power
The same 500 W, PF 0.8 load requires 625 VA from the source.
DC source current
A 60 W load supplied from 24 V through a 90% efficient converter needs about 2.78 A at the 24 V source.
Rail conversion
A 5 V, 4 A load is 20 W; from 12 V at 85% efficiency it draws about 1.96 A, not 4 A.
Path drop
A 2.78 A source current through 0.18 ohm round-trip resistance drops 0.50 V and loses about 1.39 W.
Load voltage
A 24.0 V source minus 0.50 V distribution drop leaves 23.5 V at the converter input.
Nominal energy
A nominal 12 V, 10 Ah battery is a 120 Wh label-level estimate.
Usable energy
At 80% usable capacity and 90% conversion efficiency, 120 Wh yields 86.4 Wh at the load.
Runtime
An 86.4 Wh usable budget at 18 W average load gives a first-order 4.8 h runtime.
Duty cycle
A 30 W active load at 20% duty plus 2 W idle at 80% duty averages 7.6 W before conversion losses.
Common Mistakes
Related Calculators
Support reference
FAQ
What is the difference between watts and volt-amperes?
Watts measure real power; volt-amperes measure apparent power from RMS voltage times RMS current. Their ratio is power factor.
How do I calculate AC current from power?
For single-phase AC, use current equal to real power divided by RMS voltage and total power factor, subject to waveform and topology assumptions.
Is power factor the same as efficiency?
No. Power factor relates real to apparent input power. Efficiency relates useful output power to real input power.
How do I calculate power-supply input current?
Divide required output power by efficiency to get real input power, then divide by source voltage for DC or by RMS voltage and power factor for single-phase AC.
Why is input current different from output current?
A converter transfers power between different voltages and also has losses. Current changes approximately with the inverse voltage ratio after efficiency is included.
How do I calculate voltage drop?
Multiply current by total path resistance, including supply and return conductors, connectors, protection devices, switches, and PCB paths.
How much voltage-drop margin should I allow?
Set the limit from the load minimum input, source tolerance, transient behavior, regulation, temperature, and reliability requirements rather than one universal percentage.
How do I convert battery capacity to energy?
Multiply ampere-hours by an appropriate battery voltage for a first estimate. Accurate energy requires integrating voltage over discharge.
How do I estimate battery runtime?
Divide usable battery energy by time-weighted average source power, then apply conversion, temperature, rate, aging, and SOC-window derating.
Why does actual runtime differ from the calculation?
Battery voltage curve, rate capability, cutoff, temperature, aging, converter efficiency, standby demand, and load peaks all change usable energy.
Should I size a supply from average or peak current?
Check both. Thermal and energy budgets use suitable averages, while regulation, current limit, wiring, connectors, and startup must tolerate relevant peaks.
How should I validate a power budget?
Measure real input power, RMS current, rail currents, endpoint voltages, peak events, temperatures, battery discharge, and shutdown threshold under real operating modes.
Summary
Separate real and apparent power, refer load power through conversion efficiency, calculate current at each rail, close the voltage-drop loop, and estimate runtime from usable energy and time-weighted source power. Verify both average budgets and peak constraints on hardware.